-40%
L4064B 2236 Honeywell L4064B 2772 L4064 A & E Fan & Limit 8" Furnace Resideo
$ 68.61
- Description
- Size Guide
Description
HONEYWELL/ResideoFan & Limit Control
L4064B2236
L4064B2772
L4064A
L4064E
8" Insertion
Brand New!
NOT 15 years old like others sold on eBay as New!
Product Specifications
Description
Fan and Limit Controller with 125 F fan on
and 100 F fan off stops, 200 F high limit stop
and 8 in. insertion
Application
Forced warm air heating systems
High Limit Temperature Range (F)
100 F to 250 F
High Limit Temperature Range (C)
38 C to 121 C
Element Insertion Length (in.)
8 in.
Fan-on Range (F)
65 F to 215 F
Fan-on Range (C)
18 C to 102 C
Fan-off Range (F)
50 F to 200 F
Fan-off Range (C)
10 C to 93 C
High Limit Stop (F)
200 F
Fan-on Stop (F)
125 F
Fan-off Stop (F)
100 F
Switching Action
Fan switch makes and high limit switch breaks
on temperature rise.
Electrical Rating Fan (AFL)
14 A @ 120 Vac
Electrical Rating Fan (AFL)
7 A @ 240 Vac
Electrical Rating Fan (ALR)
84 A @ 120 Vac
Electrical Rating Fan (ALR)
42 A @ 240 Vac
Electrical Rating Limit (AFL)
4 A @ 240 Vac
Electrical Rating Limit (AFL)
8 A @ 120 Vac
Electrical Rating Limit (ALR)
24 A @ 240 Vac
Electrical Rating Limit (ALR)
48 A @ 120 Vac
Pilot Duty Ratings
2 A @ 24 Vac
Pilot Duty Ratings
0.25 A @ 0.25 to 12 Vdc
Operating Temperature Range (F)
-40 F to +190 F
Operating Temperature Range (C)
-40 C to +88 C
Differential Temperature (F)
High limit 25 F
Differential Temperature (C)
High limit 14 C
Maximum Ambient Temperature (F)
Switch: 190F; Sensing Element: 350 F
Maximum Ambient Temperature (C)
Switch: 88 C; Sensing Element: 177 C
Mounting
Rigid bracket
Dimensions (in.)
Dimensions (mm)
109 mm high x 76 mm wide x 40 mm deep excluding element
Approvals, Underwriters Laboratories Inc
Listed File MP466, Guide MBPR
Approvals, Canadian Standards Association
Certified: File No. LR1622
Comments
Turns fan on and off according to plenum temperature.
With helical bimetal sensing element. High limit stop set
at 200F (93 C). With manual fan switch. Deluxe cover.
Replaces L4064A,B,E.
Please note some of the items require professional knowledge and skills to handle or installed. Thomas New Parts is not responsible for any damage or injuries resulted from mishandling of professional products. All HVACR equipment should be serviced/installed by certified professionals only. Please let us know if you have any concerns or questions.
Before Opening a Return Request or eBay Resolution Case
Please contact us through the eBay message center and let us know how we can help!